The measurement accuracy and service life of a magnetic level gauge depend to a large extent on whether on-site installation is standardized. This type of instrument transmits the level signal through magnetic coupling between the float and the indicator flaps, and it has relatively strict requirements on installation attitude, surrounding magnetic fields, and medium conditions. The following points require particularly strict control.

Verticality is the first prerequisite for installation. The main tube of the level gauge must be kept vertical to the horizontal plane. The angle should generally be no less than 87°, with a deviation controlled within 2°; in high-precision applications, a deviation of ≤0.5° may even be required. Once the gauge is tilted, the float is likely to rub against the tube wall as it moves inside the tube—causing at best sluggish indication and at worst jamming and failure to move. During installation, a spirit level or plumb line should be used to calibrate in two mutually perpendicular directions; visual judgment alone is not acceptable. For ordinary types longer than 3 m or corrosion-resistant types longer than 2 m, intermediate supports or reinforcing flanges must also be added to prevent bending deformation of the tube caused by its own weight and medium impact.
Magnetic interference prevention is a key installation discipline that distinguishes magnetic level gauges from other level instruments. No magnetic conductive materials or electromagnetic equipment may be placed within 200 mm of the instrument. Iron tools, iron-wire fastening, and ordinary steel supports should all be avoided. If heat tracing is required, the tracing pipe must be made of non-magnetic material such as copper tube. The remote transmitter and the main tube should be fixed with stainless steel clamps; iron clamps are strictly prohibited. The sensing surface must face the main tube directly, and the zero position must be horizontally aligned with the local indication zero position.
Process connection and location selection are equally important. The installation point should avoid material inlet/outlet ports and areas near agitators, so as to prevent fluid turbulence from causing severe level fluctuations and affecting reading stability. A ball valve or root valve should be installed between the level gauge and the vessel nozzle to facilitate future maintenance, cleaning, and isolation. When connecting flanges, the gasket material must be compatible with the medium, and the bolts should be tightened diagonally and in stages to prevent flange misalignment, which could lead to leakage or deformation of the instrument body.

Float insertion and commissioning are key steps at the end of installation. Magnetic level gauge when opening the bottom flange to insert the float, it must be ensured that the magnetic end faces upward; reverse installation is strictly prohibited. During commissioning, first open the upper nozzle valve, then slowly open the lower valve to allow the medium to enter the main tube smoothly. Then perform three “blowdown–drain–refill” cycles and observe whether the flaps turn over continuously and synchronously. Only after confirming that there is no jamming may the instrument be formally put into operation. Only when the commissioning process is done solidly can installation quality truly be converted into long-term reliable measurement performance.
Prev: Nighttime Measurement Performance of Glass Plate Level Gauges
Next: Common application scenarios for float liquid level switches in the petrochemical industry
Hot news
Vacorda Instruments Showcases at the 2026 Chengdu Petrochemical Technology and Equipment Expo
Vacorda Instruments made a striking appearance at Booth B225 in Hall 7, showcasing its full range of industrial measurement and control products alongside customized solutions for the petrochemical industry.
On August 12, 2026, the 34th China International Measurement Control and Instrumentation Exhibition (MICONEX) grandly opened at the Hefei Binhu International Convention and Exhibition Center. As a national-level high-tech and "Specialized, Refined, Distinctive, and Innovative" (SRDI) enterprise in the field of industrial automation instrumentation, Sichuan Vacorda Instrument Manufacturing Co., Ltd.
On June 29, 2026, Vacorda Instruments marked the milestone of its 30th anniversary. Since its inception in 1996, the company has remained steadfast in the field of process industry automation instrumentation. Upholding quality through craftsmanship and driving growth through innovation, Vacorda has evolved from a startup team into a professional industrial measurement instrument manufacturer—possessing both core technical capabilities and significant market influence—thereby writing a success story of industrial enterprise.
On June 9, 2026, the 2026 China International Petroleum & Chemical Technology and Equipment Exhibition opened at the Shanghai New International Expo Centre. Sichuan Vacorda Instrument Manufacturing Co., Ltd., a national high-tech and specialized enterprise in the field of industrial automation instrumentation,
Vacorda Instruments showcased at the 31st Azerbaijan International Oil and Gas Exhibition
As a high-tech and specialized enterprise deeply rooted in the field of industrial automation instrumentation, Sichuan Vacorda Instrument Manufacturing Co., Ltd. made a strong debut at this international industry event, showcasing its core measurement and control instruments and customized solutions for the entire oil and gas industry. This demonstrated the company's robust "Made in China" capabilities.
As a high-tech and specialized enterprise deeply rooted in the field of industrial automation instrumentation, Sichuan Vacorda Instruments Manufacturing Co., Ltd. made a strong debut at this international industry event,