LG-B Throttling Devices Orifice Plate Flowmeters
Nominal Diameter: DN10 – DN1200
Measuring Accuracy: ±0.5%, ±1%, ±1.5%
Flow Range: ≥ 1:15
Nominal Pressure: 0.6, 1.0, 1.6, 2.5, 4.0, 6.4, 10 (MPa)
Measured Medium: Saturated steam, superheated steam, water, air, natural gas, other mixed media
Medium Temperature: -10 ℃ ~ +450 ℃
Category:
Keywords:
Product Details
Products Instructions
In Petroleum, chemical industry, metallurgy, electric power, textile, military industries manufacturing process, now widely use the throttling device for fluid flow measurement and control. Like standard orifice plate flow meters. Our company manufacture a variety of throttling device that conform to international standard ISO5167:2003 and national standard GB/T2624-2006. Also manufacture widely used special throttling device such as 1/4 circular nozzle, double orifice plate and segmental orifice plate, conical entrance orifice plate, venturi tube etc.
Our company sincerely according user requirements or user’s drawings to manufacture throttling device and accessories.
Product Features
1.Throttle device structure is easy to copy, stable and reliable performance, long use period;
2.Orifice plate calculation using international standards to produce, it can put into use without real-time calibration;
3.Wide range of applications, can measure all the single-phase flow, also applied to some mixed-phase flow;
4.Wide measuring range, greater than 10: 1;
5.Simple installation, no need of pressure tube, it can be directly connected to the differential pressure transmitter and pressure transmitter;
6.With a variety of communication interfaces;
7.Intelligent orifice plate flow meter also has the fuction of self-diagnosis and set their own range.
Product Parameters
| Nominal Diameter | DN10 – DN1200 |
| Measuring Accuracy | ±0.5%, ±1%, ±1.5% |
| Flow Range | ≥ 1:15 |
| Nominal Pressure | 0.6, 1.0, 1.6, 2.5, 4.0, 6.4, 10 (MPa) |
| Measured Medium | Saturated steam, superheated steam, water, air, natural gas, other mixed media |
| Medium Temperature | -10~+450℃ |
| Power Supply | Intelligent flow totalizer 220VAC, flow transmitter 24VDC (by the totalizer power supply) |
| Output Signal | 4-20mA DC or RS485 communication |
| Explosion-proof | Intrinsically safe ibiICT5 |
Products Structure
1. Standard orifice plate, pressure taps is carrier ring, see figure a
Types of Orifice Plates
Concentric Orifice Plate: The most common type, with a hole in the center. Used for general applications with clean fluids.
Eccentric Orifice Plate: The hole is offset from the center. Suitable for fluids with solids or slurry to prevent clogging.
Segmental Orifice Plate: A segment of the plate is removed, creating a semicircular opening. Used for measuring flows of slurry or fluids with entrained gases.
By understanding these components, principles, and considerations, users can effectively implement and maintain Orifice Plate Flowmeters for accurate and reliable flow measurement in various industrial processes.
Orifice Plate Flowmeter With LED Display Flow Transmitter

Advantages
Simplicity: Simple design with no moving parts, making it reliable and easy to maintain.
Cost-Effective: Low initial cost compared to other flow measurement technologies.
Versatility: Suitable for a wide range of fluids and operating conditions.
Standardization: Widely accepted and standardized, making it easy to implement and integrate into existing systems.
Installation and Maintenance
Installation: The orifice plate is typically installed between two flanges in the pipeline. It is crucial to ensure proper alignment and correct positioning of the pressure taps.
Maintenance: Regular inspection and cleaning are necessary to prevent blockage or wear of the orifice plate. Calibration of the differential pressure transmitter should be performed periodically.
Considerations
Pressure Loss: The orifice plate introduces a permanent pressure loss in the system, which should be accounted for in system design.
Accuracy: The accuracy of the measurement can be affected by factors such as flow profile, pipe roughness, and presence of debris. Proper installation and maintenance are essential for reliable measurements.
Flow Range: The orifice plate must be correctly sized for the expected flow range to ensure accurate measurements.
Beta Ratio: The ratio of the orifice diameter to the pipe diameter (beta ratio) is critical in determining the flow characteristics and should be optimized for the specific application.