A detail that cannot be ignored: it is related to the correct installation and use of the tuning fork level switch

The probe of the tuning fork position switch is two fork bodies. Based on the tuning fork design, piezoelectricity is used to realize the vibration drive and detection of the fork body.The Huikeda tuning fork position switch reasonably increases the fork area, greatly improves the measurement sensitivity, and reduces the density of the measurable material to 0.008g/cm.The details determine the quality.In fact, the vacorda tuning fork position switch still has many unknown humanized design and details that need to be paid attention to when using it. Understanding and mastering helps to better install and use the tuning fork switch. It can make the measurement result of the tuning fork position switch more accurate.1  The role of the small dot in the course connection   Whether the tuning fork switch is installed correctly can be confirmed by observing the small dots connected in the process.  A small dot indicates that the state above or below is correct, and the left or right is wrong. When    is installed on the side, the two fork bodies of the tuning fork must be on the same level and cannot rise once.2  Blue Heather’s moisture-proof and waterproof design  The blue connector of the tuning fork switch can be rotated, but when it cannot be rotated, do not use random rotation. Rotate in the opposite direction to make the cable inlet downward.   is specially designed for the side-mounted material switch, used for waterproof and moisture-proof.3   Adjust the sensitivity of the circuit module After the top cover of the tuning fork switch is loosened, the circuit module will be exposed. The circuit module has a sensitivity adjustment part, but it does not need to be adjusted under normal circumstances, so the meter is sealed with a “QC” mark at the factory. .Remember, if you really need to adjust, you must use a small screwdriver to gently adjust to the left or right, not forcefully pressing inward. When adjusted to the rightmost, the amplitude is the largest, and the leftmost amplitude is the smallest.The smaller the amplitude, the lower the measurable density of the media (for example, foam measurement in a molding machine), but it is easier to alarm for the equivalent suspension. Generally, the media does not need to be adjusted, and it is adjusted to the far right by default.4  The function of the fuzzy device  The Huikeda tuning fork switch is precisely tuned, and it is slightly suspended under normal conditions, which will not cause false alarms. The closer the fork of the tuning fork position switch is to the tail, the more sensitive it is, and it will not alarm if it is hung near the thread.However, when measuring the viscous materials of the tuning fork position switch (such as the measurement of foam pre-emitters), it is recommended to install a cleaning device on the level switch to avoid false alarms due to paper jams.

The above are a few details that need to be paid attention to during the installation and use of the Huikeda tuning fork position switch. Mastering these details and applying them correctly can give better play to the performance of the Huikeda tuning fork switch and make the operation of the Huikeda tuning fork switch more stable and reliable.


Post time: 21-09-21