How to connect the magnetic float level gauge? how to install?

This measuring tool of the magnetic float level gauge brings great convenience to our work. I believe that many manufacturers have purchased magnetic float level gauges. Now Huikeda Instruments will tell you how to connect the magnetic float level gauge. Hope it can help youWiring method of magnetic flap level gaugeThe magnetic flap level gauge generally adopts a two-wire system with a 4-20mA signal. One of the wiring methods is: the positive pole of the magnetic flap level gauge is connected to the 24V output terminal of the meter, the negative pole is connected to the positive pole of the meter’s 4-20mA input terminal, and then the negative pole of the meter’s 4-20mA input terminal is short-circuited with the negative pole of the meter’s 24V output terminal. The above wiring method can use the 24V output of the instrument as the power supply of the magnetic flap level gaugeIf the magnetic flap level gauge adopts a four-wire system, the positive and negative poles of the power supply of the magnetic flap level gauge are connected to the positive and negative poles of the power supply. The positive and negative poles of 4-20mA are respectively connected to the positive and negative poles of the 4-20mA input terminal of the meter. If a safety barrier is used, the 24 V is connected to the positive and negative terminals of the safety barrier power supply (24 V power supply) input, corresponding to the positive and negative terminals of the magnetic flap level gauge, and the positive and negative terminals of the power output are connected to the instrument The positive and negative terminals correspond.Wiring method of magnetic flap level gauge, Pay attention to the following points when wiring1. Avoid large-capacity transformers, motors or interference sources2. Unscrew the terminal cover of the junction box, pass the cable through the cable connector, and connect to the two terminals of 24VDC3. Connect the ground terminal as required4. Tighten the terminal cover of the junction box5. For explosion-proof instruments, wiring must be carried out in accordance with relevant regulations to ensure explosion-proof performanceInstallation method of magnetic float level gauge:1. Prepare bolts, nuts and gaskets, and use copper wrenches in flammable and explosive places2. Flange stop valve or ball valve connecting the upper and lower flanges of the equipment3. Connect the magnetic float level gauge4. Clean up the iron filings in the equipment and connecting equipment pipes1. The specific model of the magnetic float level gauge1. (Basic type)2. Uhz-592 magnetic float level gauge (jacket type)3. Uhz-593 magnetic float level gauge (antifreeze type)4. Uhz-594 magnetic float level gauge (anti-corrosion type) &41;;How to connect the magnetic float level gauge5. Uhz-595 magnetic float level gauge (top-mounted type)6. Uhz-596 magnetic float level gauge (rope type)7. Uhz-597 magnetic float level gauge (lining type)8. Uhz-598 magnetic float level gauge (liquefied gas type)9. Uhz-599 magnetic float level gauge (interface type and 41How to connect a magnetic float level gauge? how to install? After reading the above content, I believe everyone knows the wiring and installation methods. There are many types of magnetic float level gauges. If you don’t know which one to choose, you can consult Vacorda Instruments


Post time: 21-09-21