What are the precautions for the side-mounted magnetic float level gauge? How does it work?

side bracket type magnetic float level gauge is a type of magnetic float level gauge, the operation principle is the same, but the scope of application is slightly different. Although many people don’t know much about the magnetic float level gauge and don’t know what the structural principle is, the main technical indicators of the side-mounted magnetic float level gauge are introduced below.   1. What is the working principle of the side-mounted magnetic flap level gauge?The UHZ type magnetic levitation plate level gauge is made based on the principle of buoyancy. It indicates that the float in the magnetic levitation plate is in the main body and floats up and down with the rise and fall of the measured medium level. The magnetic unit of the inner float is used to attract the indicator in the flip plate. , So that the liquid level change in the container under test is directly obvious   2. What are the precautions for the side-mounted maglev level gauge?   Between the side cabinet type liquid level and the upper and lower liquid distribution pipes of the inspected container, at most one shut-off valve is installed to open or finally assemble the level gauge, and to facilitate the maintenance of the liquid level. When the upper and lower shut-off valves are closed, the discharge flange at the bottom of the level gauge can be opened, or the discharge screw can be removed, and clean water can be injected to clean the main body of the level gauge.  1. Install the level gauge with a flange centerline verticality of 4. When the measuring range of the level gauge is greater than 3 meters, in order to increase the strength, it is necessary to consider adding a middle reinforced flange (or climbing ear) for fixed support.   side bracket magnet type float level gauge  2. The cross-sectional area of the core wire connecting the complete set of remote level gauge transmitter and the secondary instrument should be greater than 0.8mm2. When laying parallel to the AC power supply, keep a distance of at least 20 cm. It is best to lay the iron pipe separately or use a shielded two-core cable. The shield can only be grounded at one end.   3. Select the level controller, and its contact capacity is designed according to the resistive load. For example, in the case of non-resistive or high-power loads, use intermediate relays for conversion.  4. When the liquid medium contains floating impurities and magnetic substances, do not use this level gauge (because these impurities will jam the float assembly))))))))))) ).   3. What are the main technical indicators of the basic magnetic flap level gauge?  1. Measuring range: 500~18000mm  2, accuracy: 5mm 10mm (high temperature type)).  3, working pressure 2.5MPa (normal type)))  10.0MPa (High pressure type)  32.0MPa (Ultra high pressure type)  2.5MPa (anti-corrosion type)   side bracket magnet type float level gauge   4. Medium density: 0.45~2g/cm3  5, the density difference of the medium is 0.15g/cm3 (measurement limit position))))))) ).   6. Medium temperature: -80~450  7. For the medium with a viscosity of 0.4 Pa.s and a high viscosity, or a medium that is easy to crystallize at a low temperature, the heating sleeve type liquid level gauge can be selected according to user requirements.   8. Environmental vibration: frequency 25HZ, amplitude 0.5mm9, interface flange: adopt the newer HG20592~20635-97 flange standard issued by the Ministry of Chemical Industry in 1997.   When other standards such as 10, GB, ANSI, DIN, etc. are required, it can be designed according to the needs of users.

  The technical indicators of the side-mounted magnet float level gauge have been introduced, and the purchase and use need to be determined according to the actual use. You can browse Hoyda’s product introduction to learn more about product parameter information.


Post time: 21-09-21