What is the troubleshooting method for the magnetic float level gauge?

What is the troubleshooting method for the magnetic float level gauge? When you encounter a malfunction of the magnetic float level gauge, you need to deal with it in time, so what is the troubleshooting method of the magnetic float level gauge? How to use the magnetic float level gauge? Let’s talk aboutTroubleshooting of Magnetic Float Level GaugeWhat is the troubleshooting method of the magnetic float level gaugeWhat is the reason for the inaccurate display of the magnetic float level gaugeFirst, close the upper and lower valves, check the float from the bottom up with a magnet, and check if the float is stuck. If this is the reason, remove it and clean itHow does the magnetic float level gauge swing up and downThis phenomenon is also called <; chaotic magnetic field; due to the long use time of the magnetic float level gauge and the large magnetic attenuation, the float must be replaced, but with the update of technology, this situation is very rare now. Secondly, the liquid medium may also generate large bubbles in its measuring cylinder, which will cause the float to swing. Magnets can be used to attract the flap, so that the flap can be replaced normallyPrecautions for the use of magnetic float level gauge1. It must be vertical during use. If it is tilted, it will cause friction between the magnetic float element and the inner wall of the measuring tube, wear the element, affect the use effect, and may cause measurement errors2. When designing and installing the connection channel, a pair of stop valves should be installed between the magnetic float level gauge and the installation interface. It seems to increase a little cost, but the effect is very good, which is convenient for future maintenance and cleaning. It can also be safely and conveniently disassembled and replaced when the level gauge fails.3. Various situations may occur in the industrial production process. Due to the special working principle of the magnetic float level gauge, special attention should be paid in production. Do not stack magnetic appliances or raw materials near the level gauge, which will directly lead to inaccurate measurement data. In severe cases, the magnetism of the original internal components will be damaged, making it impossible to use normallyTroubleshooting of Magnetic Float Level GaugeInstallation and maintenance of magnetic float level gauge1. The side-mounted level gauge must be installed vertically to ensure the smooth movement of the float assembly in the main body2. Side-mounted level gauge, a shut-off valve should be installed between the level gauge and the container to facilitate cleaning and maintenance3. There should be no magnetic material near the main pipe of the level gauge, otherwise it will directly affect the normal operation of the level gauge4. When the side-mounted level gauge is put into use, the lower liquid guide valve should be opened first, so that the liquid in the container can smoothly enter the main pipe of the level gauge, so as to prevent the liquid from impacting the float assembly and rising rapidly, causing the magnetic column to overturn and fail. In case of overturning failure, please use the magnetic steel to guide the magnetic levitation column once before it can be used normallyThrough the above content, we have learned about the troubleshooting methods of the maglev level gauge. When dealing with the fault of the magnetic float level gauge, you should find a professional company, such as Huikeda Instrument


Post time: 21-09-21