XT-194-2 I²C Digital Pressure Sensor Pressure Transducer
Product Details
XT - 194 - 2 I²C Digital Pressure Sensor
Product Features
- Small size and economical
- Measurement range: 0~35kPa~10MPa
- Gauge pressure and absolute pressure type
Electrical Performance
- Power supply: 3V - 5.5V DC
- External interface: Standard PH2.5 - 4P
- Output signal: I²C digital signal (pressure/temperature)
- Working temperature: - 20°C~80°C
- Storage temperature: - 40°C~125°C
- Power consumption: <1μA
- Output bus: I²C bus protocol
- Allowable over - pressure: 1.5 times full - scale range
Environmental Conditions
- Vibration: No change under the condition of 10gRMS, 20Hz~2000Hz
- Impact: 100g, 11ms
- Media compatibility: Compatible with liquid or gas of structural materials and fluororubber
Basic Conditions
- Ambient temperature: (25±1) °C
- Vibration: 0.1g(1m/s)Max
- Humidity: (50%±10%) RH
- Ambient pressure: (86 - 106) kPa
Technical Parameters
Parameter | Minimum Value | Typical Value | Maximum Value | Unit |
---|---|---|---|---|
Power supply voltage | 3 | 5 | 5.5 | VDC |
Output comprehensive accuracy | ±0.1 | ±0.2 | %FS | |
Repeatability | ±0.3 | ±0.5 | %FS | |
Hysteresis | ≤0.1 | %FS | ||
Overload pressure | ≤0.1 | 150 | %FS | |
ESD protection | 2000 | V | ||
Storage temperature | - 40~125 | °C | ||
Working temperature | - 40~100 | °C | ||
Compensation temperature range | - 20~80 | °C | ||
Long - term stability | ±0.2 | %FS/year | ||
Temperature drift coefficient | 0.005 | 0.01 | 0.02 | %FS/°C |
Power - on time | 80 | ms | ||
I²C clock speed | 50 | 400 | KHz |
Product Applications
- Industrial process control
- Intelligent pressure detection instrument
- Medical equipment
- Liquid level measurement
- Gas and liquid pressure measurement
- Internet of Things
Product Overview
The XT - 194 - 2 I²C digital pressure sensor is a digital I²C output pressure sensor provided for users. It has a built - in temperature compensation sensor, which can perform real - time compensation for zero - point error and temperature drift, sensitivity error and temperature drift, and non - linearity error of the sensor signal. The output conforms to the pressure and temperature data of the I²C interface protocol. It has high cost - performance, accurate measurement, and reliability. The internal circuit of the sensor adopts anti - static and anti - surge design, greatly enhancing the on - site adaptability. It is suitable for measuring pressure in applications that are sensitive to power consumption requirements.
Structure Material
- Diaphragm material: 316L
- Shell material: 316L
- Pressure - guiding pipe material: 316L
- Sealing ring: Viton
- Net weight: about 26g
Wiring Definition
Number | Electrical Definition | Wire Color |
---|---|---|
1 | Power supply positive (VCC) | Red |
2 | Power supply negative (GND) | Yellow |
3 | Data line (SDA) | Blue |
4 | Clock line (SCL) | Green |
Communication Protocol
XT - 194 - 2 uses the I²C bus protocol for external communication. The I²C bus uses SCL and SDA as signal lines. Both lines are connected to AVDD through pull - up resistors. The default device address of this product is OXFE, which can be changed. The device addresses are as follows:
A7 | A6 | A5 | A4 | A3 | A2 | A1 | W/R |
---|---|---|---|---|---|---|---|
1 | 1 | 1 | 1 | 1 | 1 | 1 | 0/1 |
I²C Communication Pin Electrical Characteristics
Mark | Parameter | Minimum Value | Maximum Value | Unit |
---|---|---|---|---|
fsc1 | Clock frequency | 400 | kHz | |
tLOW | Clock low - pulse duration time | 1.3 | μs | |
tHIGH | Clock high - pulse duration time | 0.6 | μs | |
tSUDAT | SDA setup time | 0.1 | μs | |
tHDDA T | SDA hold time | 0.0 | μs | |
tSUSTA | Each start setup time | 0.6 | μs | |
tHDSTA | Start condition hold time | 0.6 | μs | |
tSUSTO | Stop time setup time | 0.6 | μs | |
tBUF | Two - communication time interval time | 1.3 | μs |
Related Application