UHC Magnetic Liquid Tank Level Gauge With Level Sensor
| Measuring Range | 150~6000mm |
| Medium Density | >0.45g/cm³ |
| Nominal Pressure | PN63~PN320 (x 0.1MPa) |
| Material | 304,316L,1Cr18Ni9Ti,0Cr18Ni9,00Cr17Ni14Mo2,321, titanium or customize |
| Operating Temperature | -190 ~ +425 °C |
| Top Structure | Welding cap with 3/4"NPT vent plug |
| Bottom Structure | Flange with 3/4"NPT drain plug |
| Indicate Ruler | A: Al &ABS Flap Cylinder, B: Al Flap Plate, C:316L Flap Cylinde |
| D:316L.& Al flap plate, E:316L/AI &LED, F:316L/AI &LED | |
| Protection Class | IP65, IP67 |
| Explosion-proof | ExdII CT6Gb |
| Magnetic Alarm Switch | Switching state: SPST; SPDT Max capacity: 20w, 60W, 120W |
| Max Voltage: 230V, 250V | |
| Transmitter | Output Signal: 4~20mADC Output Load:500Ω |
| Power Supply:16~30VDC Protection Class: IP65 |
Arange 0.15-12m,PTFE Lining Anti-corrosion Design, Magnetostrictive liquid level sensor
Category:
Keywords:
Product Details
Working Principle
The UHC series magnetic column level gauge is connected to the vessel through a gas phase and liquid phase connection flange using the principle of a linker. According to the principle of buoyancy and magnetic coupling, the magnetic float in the measuring cylinder (connector) drives the two-color flip on the external display of the measuring cylinder to rise (lower) with the measured liquid level. When the liquid level rises, the magnetic float magnetic float drives the flip column to flip 180°, showing red and green; when the liquid level drops, the magnetic float drives the flip column to rotate 180° in the reverse direction, showing white. The height of the red band (or green band) is the height of the measured liquid level, which achieves the purpose of measuring and displaying the position of the measured liquid (boundary) surface.
Each magnetic flip column has a two-color axially symmetric structure with a spacing of 10 mm between the two magnetic flip columns, with white and red (green) indicating the meteorological and liquid phase portions respectively, and the red (or green) and white junctions are The boundary between the gas phase and the liquid phase. The level gauge measures both the liquid level and the interface of two different density media.
Product Standards:HG/T 2742-1995、HG/T21584-95, Flange standard:HG/T20592~20615-2009

Features
1.Simple structure, good stability, reliability and durability.
2.Isolated medium, indicator, transmitter and switch
3.Wide range of operating pressure: vacuum to 42Mpa
4.Wide range of operating temperature: -190℃ to 425 ℃
5.Independent of medium’s physical and chemical states.
6.SPST or SPDT available
7.Optioning float level transducer, capacitive two-wire level transducer and Magnetostrictive level sensor to transmit 4-20mA DC signal (or HART) and realize remote control and measurement.
8.Two-wire level transducer can be with LED digital indicator for night observation.
Product Specifications
| C-C Distance | 150~6000mm(more than 6m can be specially customized) | ||
| Medium Density | >0.45g/cm³ | ||
| Nominal Pressure | PN63~PN420 (x 0.1MPa) | ||
| Material | 304,316L,1Cr18Ni9Ti,0Cr18Ni9,00Cr17Ni14Mo2,321, titanium alloy or customize | ||
| Operating Temperature | -190 ~ +425 °C | ||
| Top Structure | Vent plug/valve,welding cover with air valve, flange with plug screw, welding cover with 1/2"NPT | ||
| Bottom Structure | Drain plug/valve, welding cover with plug screw or 1/2"NPT, flange with plug valve or ball valve | ||
| Indicate Ruler | A: Al &ABS flap cylinder | D:316L.& Al flap plate | |
| B: Al flap plate | E:316L/AI &LED | ||
| C:316L flap cylinder | F:316L/AI &LED | ||
| Protection Class | IP65,IP67 | ||
| Optional Items | |||
| Magnetic Alarm Switch | switching state: SPST; SPDT | Transmitter | Output signal: 4~20mADC |
| max capacity: 20w, 60W, 120W | Output load:500Ω | ||
| max Voltage: 230V, 250V | Power supply:16~30VDC | ||
| max current: 0.5A,1A, 2A | Protection class: IP65 | ||
| life time: ≤1x109 | Explosion-proof: ExiaII CT6Ga ExdII CT6Gb | ||
| protection class: IP65 | |||
| explosion-proof: ExdII CT6Gb | |||
Application
UHC series magnetic column liquid level gauge is widely used in petroleum, chemical industry, oil field, pharmaceuticals industry, food, wine industry etc., suitable for level measurements under the environment of high/low temperature., high pressure, strong corrosion, toxicity.

Optional Items
1.SPST or SPDT no standby power alarm switch could realize high-low level measurement and alarm. Alarm switch number is unlimited.
2.Optional two-wire magnetic liquid level sensor, output 4~20mADC signal for remote measurement and control.
3.Optional two-wire magnetostrictive and capacitive liquid level sensor, output 4~20mADC signal for high precision, continuous measurement and control.
4.Top and bottom structure connection can be selected.
5.4~20mADC + HART protocol.
Contact Us
Sichuan VACORDA Instrument Manufacturing Co., Ltd.
E-mail: sales@vacorda.com
Tel: 0086-028-87362258
7X24 hours online
Address: Guanghua Rd, Qingyang Dist, Chengdu, Sichuan Province, China