UHC Frost Proof Magnetic Level Meter With Alarm
Measuring Range 150~6000mm(more than 6m can be specially customized)
Working Pressure PN6~PN320 (x 0.1MPa)
Working Temperature -190 ~ +425 °C
Connection Method DN80-DN250/RF/14(according to the density of medium)
Communication 4~20mADC
Medium Density >0.45g/cm3
Main Materials 304,316L,304+PTFE,0Cr18Ni9,00Cr17Ni14Mo2,
PP(PP≤1.6mpa, 304+PTFE≤4mpa), or customize
Connector of Heating Stream R1/2" male thread or customize
Pressure of Stream ≤0.6mpa(please note when>0.6mpa)
Customized LED Display and Solar Powered
Protection Class IP65 IP67
Arange 0.15-12m Temperature -190 ~ +180°C PTFE Lining Anti-corrosion Design
Category:
Keywords:
Product Details
Vacorda UHC steam heating magnetic level meter It is used in tanks that can not be mounted on the side surfaces. The movement of the float in the tank according to the filling rate of the tank; the level moves the float inside the bottle and the tank observation is provided mechanically.Like other systems, the top mounted magnetic level gauges can also be manufactured for the automation systems.
Product Specifications
| C-C Distance | 150~6000mm(more than 6m can be specially customized) | ||
| Medium Density | >0.45g/cm³ | ||
| Nominal Pressure | PN6~PN320 (x 0.1MPa)(more than PN320 can be specially customized) | ||
| Material | 304,316L,1Cr18Ni9Ti,0Cr18Ni9,00Cr17Ni14Mo2,321, titanium alloy or customize | ||
| Operating Temperature | -190 ~ +425 °C | ||
| Top Structure | Vent plug/valve,welding cover with air valve, flange with plug screw, welding cover with 1/2"NPT | ||
| Bottom Structure | Drain plug/valve, welding cover with plug screw or 1/2"NPT, flange with plug valve or ball valve | ||
| Indicate Ruler | A: Al &ABS flap cylinder | D:316L.& Al flap plate | |
| B: Al flap plate | E:316L/AI &LED | ||
| C:316L flap cylinder | F:316L/AI &LED | ||
| Protection Class | IP65,IP67 | ||
| Optional Items | |||
| Magnetic Alarm Switch | Switching state: SPST; SPDT | Transmitter | Output signal: 4~20mADC |
| Max capacity: 20w, 60W, 120W | Output load:500Ω | ||
| Max Voltage: 230V, 250V | Power supply:16~30VDC | ||
| Max current: 0.5A,1A, 2A | Protection class: IP65 | ||
| Life time: ≤1x109 | Explosion-proof: ExiaII CT6Ga ExdII CT6Gb | ||
| Protection class: IP65 | |||
| Explosion-proof: ExdII CT6Gb | |||
Working Principle
The UHC type magnetic liquid level gauge is made up of measuring body,dual-colored display cylinder, ruler, top&low flange,magnetic ball and transmitter (4-20mA). Based on buoyance principle, the magnetic ball in the body of the level gauge is up or down with the liquid level changing and makes dual-colored turning to show the level of medium. Each cylinder is with two-color axisymmetric structures.The distance of two cylinders is 10mm. Red side of display cylinder indicates liquid and white side display cylinder indicates air. Besides measuring liquid level,it also could measure the interface of the two of liquid.
Product Feature
1. Level indicator magnetic type has simple structure, good stability and reliability.
2. Independent of medium’s physical and chemical states such as conductivity, dielectric constants, foam etc.
3. Appliable for all kinds of medium environment such as corrosive, toxic and explosive one.
4. Interface measurement or level measurement of 2 kinds of medium with different density.
5. Two-wire 4~20mADC signal output, 0.8"or 0.56” LED digital display.
| Structure | Installation Method |
![]() |
![]() |
Optional Item of Liquid Level Transmitter
1.Magnetic liquid level transmitter
It consists of imported reed switch, precision resistor and conversion circuit. When the magnetic flux of the magnetic float in the magnetic flip column level gauge is closed to the reed switch at a certain position, the resistance of the three-wire potentiometer is proportional to the liquid level change, and the change of the liquid level is converted into the 4~20mADC signal by the conversion circuit. Output for detection and transmission of liquid level signals.
2.Capacitive liquid level transmitter:
It consists of a measuring electrode and a conversion processing circuit. The measuring electrode is installed in the bypass tube of the magnetic flip column level meter. The electrode detects the change of the liquid level and the output of the conversion circuit is proportional to the change of the liquid level, and the output signal is not affected by the position of the float of the magnetic flip column level gauge. It has improved reliability and has the characteristics of continuous output signal.
3.Magnetostrictive level sensor
It is a new generation of liquid level sensor with high measurement accuracy. It is stable in performance and is not affected by gas, temperature and pressure changes in the tank. Two-wire 4~20mA (with HART), Modbus and other signal outputs are available.
Optional Item of Magnetic Alarm Switch
The magnetic switch is made of imported high quality reed switch. The switch contacts are available in single pole double throw (SPDT) and single pole single throw (SPST). When the magnetic float passes through the midpoint of the magnetic switch, the magnetic switch contacts are switched to a stable state and maintained; When the magnetic float passes the midpoint of the magnetic switch in the opposite direction, the magnetic switch contacts are switched to the original stable state and held.
The two stable state transitions of the magnetic switch are controlled only by the magnetic float and do not require external working power.
The magnetic switch is matched with the magnetic flip level gauge and is widely used for alarm and automatic control of various interfaces and pages.
Application Cases
Vacorda UHC series bypass level indicator magnetic type is widely used in petroleum, chemical industry, oil field, pharmaceuticals industry, food, wine industry etc.
1.All steam and hot water boilers
2. Waste water systems
3.Filling and unloading containers
4.All chemical and petrochemical tanks
5.Tanks for petroleum and petroleum products
6.Oil boilers
7.Diesel fuel tanks and generator sets
8.Submarine, helicopter and ship fuel tanks.
![]() |
![]() |
Contact Us
Sichuan VACORDA Instrument Manufacturing Co., Ltd.
E-mail: sales@vacorda.com
Tel: 0086-028-87362258
7X24 hours online
Address: Guanghua Rd, Qingyang Dist, Chengdu, Sichuan Province, China