HKLD Magnetic Flow Meter Electromagnetic Flowmeter

+
  • undefined
  • undefined
  • undefined
  • undefined

Measuring Range                                            Dn10 to Dn3000
Repeatability Error                                          +/-0.1%
Accuracy Piped                                                0.5 class, 1.0 class
Measured Medium Temperature                     Common rubber lining: -20~+60 ° c
                                                                         High temperature rubber lining: -20~+90 ° c
                                                                         PTFE lining: -30~+100 ° c
                                                                         High temperature vinyl lining: -30~+180 ° c
Rated Working Pressure                                  Pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;DN200~DN1200: ≤ 1.0MPa
Flow Measuring Range                                    Flow measuring range corresponding to flow rate range is 0.3~15m/s
Measured Fluid Conductivity                           5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)
Output                                                              Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA
Electrode Material                                            316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials


LCD Display, Wireless Signal Output, Accepting Customization

Keywords:

Inquiry

Product Details


undefined

Product Instructions
Working principle of electromagnetic flowmeter measurement principle is based on the Faraday law of electromagnetic induction. Measurements of the flow meter tube is lined with insulating material of a non-magnetic alloy spool. Two clicks along the diameter through-wall fixing on the measuring tube. The electrode head is flush with the lining inner surface. Field coil by waves when pulsed excitation by both parties, will be measured perpendicular to the pipe axis direction produces a magnetic flux density of the magnetic field b. At this point, if you have some electrical conductivity of fluid flows through the measuring tube, cut magnetic lines of induction electromotive force E. Electromotive force e is proportional to the magnetic flux density B, measure the inside diameter d and the product of the mean velocity v. Electromotive force e (traffic signal) checked out by electrodes and cables to the converter. Converter after the traffic signal will be amplified, to display fluid flow and energy output pulse, analog current signals for flow control and the flow adjustment.

The Characteristics And Advantages Of Vacorda Electromagnetic Flow Meter
1.Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and electrical conductivity;
2.There are no flow blocking components inside the measuring tube, no pressure loss, low requirements for straight sections, and unique adaptability for slurry measurement.
3.The nominal diameter of DN6-DN3000 covers a wide range, with multiple options for lining and electrodes, suitable for various measurement media, and has good corrosion resistance and wear resistance;
4.The converter adopts programmable frequency low-frequency rectangular wave excitation, which improves the stability of flow measurement and reduces power loss;
5.The converter adopts a 32-bit embedded microprocessor with full digital processing, fast calculation speed, strong anti-interference ability, reliable measurement, high accuracy, and a flow measurement range of 1500:1. The range can be modified online according to the actual needs of users;
6.High definition backlit LCD display, optional menu operation in both Chinese and English, convenient to use, easy to operate, easy to learn and understand;
7.Equipped with digital communication signal outputs such as RS485, RS232, Hart, and Profibus (optional);
8.Has conductivity measurement function, can distinguish whether the sensor is empty tube, and has self check and self diagnosis functions;
9.Adopting SMD devices and surface mount (SMT) technology, the circuit has high reliability;
10.Infrared manual operator operation, 115KHZ communication speed, remote non-contact operation of all functions of the converter (optional);
11.There are three internal meters that can display the forward cumulative quantity, reverse cumulative quantity, and difference cumulative quantity respectively. There is an internal power-off clock that can record the power-off time (optional);
12.Can be used in corresponding explosion-proof situations.

 

Product Structure


Technical Parameters

PTFE Lined Pipe(Dn) 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600
Rubber Lined Pipe(Dn) 40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized
Measuring Range Ratio 150:01:00
Repeatability Error +/-0.1%
Accuracy Piped: 0.5 class, 1.0 class
Measured Medium Temperature Common rubber lining: -20~+60 ° c
High temperature rubber lining: -20~+90 ° c
PTFE lining: -30~+100 ° c
High temperature vinyl lining: -30~+180 ° c
Rated working pressure Pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;
DN200~DN1200: ≤ 1.0MPa
Flow Measuring Range Flow measuring range corresponding to flow rate range is 0.3~15m/s
Measured Fluid Conductivity 5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)
Output Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA
Electrode Material 316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials


Product Application Cases

 

Contact Us
Sichuan VACORDA Instrument Manufacturing Co., Ltd.
E-mail:    sales@vacorda.com
Tel:            0086-028-87362258
                 7X24 hours online
Address: Guanghua Rd, Qingyang Dist, Chengdu, Sichuan Province, China

* Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible

+86
  • +86 CN
Submit