Measuring Medium                                          Liquid, gas, saturated steam, superheated steam
Medium Flow Rate                                            Liquid 0.5~7 m/s, gas 4~40 m/s, steam 7~70 m/s
Accuracy level                                                   Liquid 1.0, gas 1.5, insert type 2.5
Normal Measurement Range                            Reynolds number is 2*104~7*106
Nominal Diameter                                             DN15~DN300 (pipeline type, clamping),
Medium Temperature                                        -40~80°C, medium temperature -40~250°C, high temperature -40~350°C
Nominal Pressure                                              1.0~6.3MPa (>6.3 for customize)
Installation Method                                           Flange type, insert type, clamp type
Power Supply                                                     3-wire pulse output 12V, 24VDC optional
                                                                           2-wire power supply 24VDC
Local Display Type                                              3.6V lithium 7.5AH battery, life > 2 years
Load Resistance                                                  500Ω (when powered by 24VDC)
Body Material                                                     SS304, SS316L (or for customize)
Head Materia                                                     Cast aluminum housing, stainless steel housing (or for customize)
Protection Level                                                 IP65


High Accuracy, Insert Type, Anti-Interference and Anti-Vibration, Pulse Signal Output

Keywords:

Inquiry

Product Details


Product Instructions
The LUGB type vortex flowmeter is a flowmeter designed and manufactured using the Karman principle theory of the relationship between the generation of vortices and the flow rate. It can be used to measure the flow of steam, gas and low viscosity liquids. A triangular column (vortex) generating body is inserted into the fluid, and a regular Karman vortex is formed alternately behind the triangular prism, and the separation frequency of the scoring is proportional to the flow velocity(V) of the measured medium. Therefore, the flow rate of the measured fluid can be calculated by detecting the number of vortices by the flow meter sensor head, and the signal processing circuit calculates the volume flow rate of the measured medium according to the sensor aperture.

Product Feature
1.No Moving Parts: Ensures long-term stability, simplicity in structure, easy installation, and maintenance.
2.Pulse Signal Output: The sensor outputs a pulse signal with a frequency linearly proportional to the actual flow rate of the measured fluid. Zero drift is eliminated, ensuring highly stable performance. Available in various structural forms, including pipeline and insertion flow sensor types.
3.High Accuracy: The measurement accuracy is typically ±1.0% for liquids and 1.5% for gases.
4.Wide Measurement Range: Covers a broad measurement range, with a Reynolds number range of 2×10⁴ to 7×10⁶, achieving a ratio of up to 1:20.
5.Low Pressure Loss: The pressure loss is about 1/4 to 1/2 that of an orifice flow meter, making it an energy-saving flow instrument.
6.Flexible Installation: Can be installed horizontally, vertically, or at various angles, accommodating different process pipeline configurations.
7.Anti-Interference and Anti-Vibration: Equipped with an anti-interference circuit and vibration-resistant sensor head, providing some resistance to environmental vibrations.
8.Non-Linearity Correction: Software corrects the instrument coefficient's non-linearity, improving measurement accuracy.
8.Low Pressure Loss, Wide Range: Ensures minimal pressure loss and a broad measurement range.
9.EEPROM Data Protection: Cumulative flow data is protected against power failure using EEPROM, with protection lasting over 10 years.

Product Parameter

Measuring Medium Liquid, gas, saturated steam, superheated steam
Medium Flow Rate Liquid 0.5~7 m/s, gas 4~40 m/s, steam 7~70 m/s
Accuracy Level Liquid 1.0, gas 1.5, insert type 2.5
Possible Range of Measurement Reynolds number is 5*103~7*108
Normal Measurement Range Reynolds number is 2*104~7*106
Nominal Diameter DN150~DN2000 (insert type or customized)
Medium Temperature -40~80°C, medium temperature -40~250°C, high temperature -40~350°C
Nominal Pressure 1.0~6.3MPa (>6.3 for customize)
Installation method: Flange type, insert type, clamp type
Output Signal Voltage pulse: low level ≤ 1V, high level ≥ 6V
2-wire system 4-20mA (with RS485, HART)
Pulse frequency 0.1~3000Hz
Power Supply 3-wire pulse output 12V, 24VDC optional
2-wire power supply 24VDC
Local display type 3.6V lithium 7.5AH battery, life > 2 years
Load Resistance 500Ω (when powered by 24VDC)
Electrical Interface M20*1.5, 1/2" NPT
Body Material SS304, SS316L (or for customize)
Head Material Cast aluminum housing, stainless steel housing (or for customize)
Environmental Conditions Temperature -20~+60, relative humidity 5% ~ 90%
Protection Level IP65
Explosion-proof Grade ExdIIBT4Gb, ExiaIIBT4Ga


Product Applications
Vortex flow meter is suitable for the flow measurement of liquid, gas, and steam.

 

Contact Us
Sichuan VACORDA Instrument Manufacturing Co., Ltd.
E-mail:    sales@vacorda.com
Tel:            0086-028-87362258
                 7X24 hours online
Address: Guanghua Rd, Qingyang Dist, Chengdu, Sichuan Province, China

* Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible

+86
  • +86 CN
Submit