HKR Borosilicate Water Tank Level Indicator With Bicolor Light
Center to Center Distance 0~300-0~2000mm
Recommended Length 550, 850, 1150, 1450, 1750mm
Material Carbon steel, SS304, SS316L
Nominal pressure (MPa) Transparent type: 2.5, 6.3;
Reflective type: 4.0;
Sight glass type: 0.1, 0.6
Working Temperature 0~250℃
Connection Flange DN20 (3/4”) HG/T 20592-2009
Heating Steam Cube Connector RC1/4 internal thread
Heating Steam Pressure ≤1.0MPa
Steel Ball Closing Pressure ≥0.3MPa
High Temperature, No Blind Spots, Side Mounted, Boiler Level Meter With LED Light
Category:
Keywords:
Product Details
Product Description
The glass plate liquid level meter is divided into three types: light-transmitting, reflective and mirror-type. The liquid level meter is mainly composed of a liquid level meter body, an upper valve (a steam valve), a lower valve (a liquid valve), a sewage plug (sewage valve), and an insurance steel ball. When the glass plate is damaged by splitting or the like, the safety steel ball automatically blocks the gas and liquid side valves to prevent or reduce the outflow of the medium, and is convenient for manually cutting the root valve of the liquid level meter for processing. The series is sturdy, reliable and easy to install. It is an ideal instrument for liquid level observation in various medium and low pressure vessels.
The liquid level gauge is connected to the upper and lower flanges of the liquid level meter and the upper and lower flanges of the container to form a communicating device, so that the liquid level can be directly observed.

Product Features
1. Directly observe the liquid level position;
2. It has a quick shut-off device for vapor and liquid leakage;
3. Reasonable structure, simple installation and maintenance;
4. Low maintenance costs;
Technical Specifications
| Center to Center Distance | 0~300-0~2000mm |
| Recommended length | 550, 850, 1150, 1450, 1750mm |
| Material | Carbon steel, SS304, SS316L |
| Nominal pressure (MPa) | Transparent type: 2.5, 6.3; Reflective type: 4.0; Sight glass type: 0.1, 0.6 |
| Working Temperature | 0~250℃ |
| Connection Flange | DN20 (3/4”) HG/T 20592-2009 |
| Heating Steam Cube Connector | RC1/4 internal thread |
| Heating Steam Pressure | ≤1.0MPa |
| Steel Ball Closing Pressure | ≥0.3MPa |
Transportation and Installation
1. The instrument should be handled with care during transportation, handling, unpacking and installation. Do not hit, knock or prevent the glass plate from rupturing. This product has been assembled and debugged before leaving the factory, and the pressure test is completed. Users should not loosen the fasteners at random, otherwise the pressure tightness test should be carried out.
2. When installing, the center distance of the upper and lower flanges of the user equipment container, the flange size and the flange orientation must be consistent with the center distance of the instrument, the flange specification and the flange orientation. Otherwise, the installation cannot be performed.
3. In order to ensure the safe operation of the user, the user must install a primary valve on the upper and lower flanges of the container and the upper and lower flanges of the instrument, and at the same time provide guarantee for the maintenance and maintenance of the instrument.
4. When installing, the sealing surface of the connecting flange of the container equipment should be on the same plane and the mounting screw holes are symmetrical. The installation of the instrument shall not have any additional pressure applied to the glass plate to prevent the glass plate from being broken during installation or operation.
5. Check the sealing points after installation and maintenance, and there must be no leakage.
6. The liquid glass meter should not be replaced by organic glass or ordinary glass.
Operation and Maintenance
After the instrument is connected to the flange of the container, the pressure test shall be carried out according to the regulations, and the use shall be allowed only after the requirements are met.
Preparation
1. Open the drain valve (plug);
2. Slowly open the upper valve (steam valve). When the temperature difference between the ambient temperature and the medium temperature is greater than 40 degrees, the liquid level meter must be preheated. After the temperature of the liquid level meter reaches the medium temperature, the valve can be opened gradually until all Open
3. Slowly close the drain valve (plug), observe the level gauge and each joint, if there is leakage, it should be treated;
4. After no leakage, slowly open the lower valve (water valve) to observe whether the water level is normal;
5. Fully open the upper and lower valves to put the liquid level meter into operation
Operation and Maintenance
1. It is strictly forbidden to observe the water level during operation;
2. Pay attention to the leakage of the sealing ring. If there is any leakage, it should be handled in time to avoid media leakage and injury;
3. When the contamination inside the glass plate cannot be observed, close the vapor-liquid side valve and open the drain valve (plug). After the pressure is completely relieved and the medium is drained, the glass plate can be removed for cleaning. After re-installation, it must be confirmed. No leakage can be put into use;
Structure


Applications
Glass level gauge mainly used widely used in petroleum, chemical, electric power, metallurgy and other industries a variety of transparent liquid containers and boilers, water, gasoline, liquefied petroleum gas, ammonia, propane, propylene, aromatics, acids and other oil products and chemical raw materials level measurement.