LWY Separated Remote LVD Display Turbine Flow Meter
Nominal Diameter DN6~DN200
Medium Clean liquid, such as water, oil...
Viscosity 5~400mpa.s
Operating Temperature -20~120℃
Nominal Pressure PN16~PN63
Flow Range ≤1200m3/h
Accuracy 0.5, 1.0, 1.5
Body Material 304, 321, 316L
Impeller Material 2Cr13, Dual-phase steel
Ambient Temperature -20~60℃; RH:5~90%
Signal Output Pulse, 4~20mA, RS485, HART
Working Power 24VDC±15%
Li-battery 3.6V10AH (No signal output)
Explosion Proof ExdⅡBT4; Protection grade: IP65
Electric Interface M20×1.5
Process Connection Flange or thread connection
High Accuracy, Insert Type, Anti-Interference and Anti-Vibration, Pulse Signal Output
Category:
Keywords:
Product Details
Description
LWYB series turbine flow meters, based on the torque balance principle, belong to the speed flow meter. The sensor has the characteristics of simple structure, light skill, high accuracy, good recovery, sensitive response, convenient installation and maintenance and use. The turbine flow meter is suitable for measuring liquids or gases compatible with stainless steel 1Cr1-8Ni9Ti, 2Cr13, Corundum Al2O3 and carbide and free of impurities such as fibers and particles. The sensor is suitable for medium with viscosity less than 5*10-6 m²/s. For liquid with viscosity greater than 5*10-6 m²/s, the sensor should be calibrated with the real measured liquid.
Working Principle
When the measured liquid flows through the sensor, because the impeller blade has a fixed Angle with the flow direction, the impeller receives the kinetic energy of the fluid under the action of the fluid, the impeller rotates after overcoming the friction torque and fluid resistance, and the impeller speed is constant after the balance of each torque. Under certain conditions, the impeller speed is proportional to the average pipeline flow rate. The rotation of the impeller periodically changes the induced potential of the detection coil, that is, the electric pulse signal, which is an amplifier, plastic output pulse signal or 4 ~ 20 m ADC signal to display the instantaneous flow value or total amount. In a certain flow range, the pulse frequency F is proportional to the instantaneous flow rate of the fluid flowing through the flow meter sensor, with the calculation formula
|
Q=3600*F/K |
In the formula: Q— Instantaneous delivery (m³/h) F— Pulse frequency (Hz) K— Instrument coefficient(Pulse/m³), given by verification |
Technical Specifications
| Nominal Diameter | DN6~DN200 |
| Medium | Clean liquid, such as water, oil... |
| Viscosity | 5~400mpa.s |
| Operating Temperature | -20~120℃ |
| Nominal Pressure | PN16~PN63 |
| Flow Range | ≤1200m3/h |
| Accuracy | 0.5, 1.0, 1.5 |
| Body Material | 304, 321, 316L |
| Impeller Material | 2Cr13, Dual-phase steel |
| Ambient Temperature | -20~60℃; RH:5~90% |
| Signal Output | Pulse, 4~20mA, RS485, HART |
| Working Power | 24VDC±15% |
| Li-battery 3.6V10AH (No signal output) | |
| Explosion Proof | ExdⅡBT4; Protection grade: IP65 |
| Electric Interface | M20×1.5 |
| Process Connection | Flange or thread connection |
| Instalation | Horizontal |
Pulse Output Intelligent Turbine Flowmeter
1.Working Voltage: external power supply 220VAC or 24VDC power supply (optional)
2.Signal Transmission Distance: less than 300 meters.
3.Instantaneous Display: four bits , total cumulative display: nine bits
4.Display Instrument Size:
Horizontal type: 160mm * 80mm;
Vertical Type: 80mm * 160mm
The display instrument has 4-20mA output RS485 communication and can be connected to the computer.