PP Anti-corrosion Type Magnetic Liquid Level Gauge With Level Switch

+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Measuring Range                        150~4000mm
Working Pressure                        PP:PN2.5~PN16(x0.1MPa)
Working Temperature                 PP:≤80℃(reach100℃ when atmospheric pressure)
Connection Method                    DN80-DN250/RF/14(according to the density of medium)
Communication                          4~20mADC
Medium Density                         >0.45g/cm3
Main Materials                           304,316L,304+PTFE,0Cr18Ni9,00Cr17Ni14Mo2,PP(PP≤1.6mpa, 304+PTFE≤4mpa), or customize
Protection Class                         IP65
Customized                                LED Display and Solar Powered


Measuring Range 1.5M~4M 4~20mADC Signal Output LED Display and Solar Powered

Keywords:

Inquiry

Product Details


Description
The UHC series magnetic column level gauge is connected to the vessel through a gas phase and liquid phase connection flange using the principle of a linker. According to the principle of buoyancy and magnetic coupling, the magnetic float in the measuring cylinder (connector) drives the two-color flip on the external display of the measuring cylinder to rise (lower) with the measured liquid level. When the liquid level rises, the magnetic float magnetic float drives the flip column to flip 180°, showing red and green; when the liquid level drops, the magnetic float drives the flip column to rotate 180° in the reverse direction, showing white. The height of the red band (or green band) is the height of the measured liquid level, which achieves the purpose of measuring and displaying the position of the measured liquid (boundary) surface.
Each magnetic flip column has a two-color axially symmetric structure with a spacing of 10 mm between the two magnetic flip columns, with white and red (green) indicating the meteorological and liquid phase portions respectively, and the red (or green) and white junctions are The boundary between the gas phase and the liquid phase. The level gauge measures both the liquid level and the interface of two different density media.
Product Standards:HG/T 2742-1995、HG/T21584-95, Flange standard:HG/T20592~20615-2009


Features
1.Simple structure, good stability, reliability and durability.
2.Isolated medium, indicator, transmitter and switch 
3. Wide range of operating pressure: vacuum to 42Mpa
4. Wide range of operating temperature: -190℃ to 425 ℃
5. Independent of medium’s physical and chemical states.
6. SPST or SPDT available
7. Optioning float level transducer, capacitive two-wire level transducer and Magnetostrictive level sensor to transmit 4-20mA DC signal (or HART) and realize remote control and measurement.
8. Two-wire level transducer can be with LED digital indicator for night observation.


Product Specifications

C-C Distance 150~4000mm(more than 4m can be specially customized)
Medium Density >0.45g/cm3
Nominal Pressure PP:PN2.5~PN16(x0.1MPa)
Material 304,316L,1Cr18Ni9Ti,0Cr18Ni9,00Cr17Ni14Mo2,321, titanium alloy or customize
Operating Temperature PP:≤80℃(reach100℃ when atmospheric pressure)
Top Structure Vent plug/valve,welding cover with air valve, flange with plug screw, welding cover with 1/2"NPT
Bottom Structure Drain plug/valve, welding cover with plug screw, welding cover with 1/2"NPT, flange with plug valve or ball valve
Indicate Ruler A: Al &ABS flap cylinder
B: Al flap plate
C:316L flap cylinder
D:316L.& Al flap plate
E:316L/AI &LED
F:316L/AI &LED
T:316L/AI &LED solar powered
Protection Class IP65
Optional Items
Magnetic Alarm Switch switching state: SPST; SPDT
max capacity: 20w, 60W, 120W
max Voltage: 230V, 250V
max current: 0.5A,1A, 2A
life time: ≤1x109
protection class: IP65
explosion-proof: ExdII CT6Gb
Transmitter output signal: 4~20mADC
output load:500Ω
power supply:16~30VDC
protection class: IP65
explosion-proof: ExiaII CT6Ga ExdII CT6Gb


Optional Items
1. SPST or SPDT no standby power alarm switch could realize high-low level measurement and alarm. Alarm switch number is unlimited.
2. Optional two-wire magnetic liquid level sensor, output 4~20mADC signal for remote measurement and control.
3. Optional two-wire magnetostrictive and capacitive liquid level sensor, output 4~20mADC signal for high precision, continuous measurement and control.
4. Top and bottom structure connection can be selected.
5. 4~20mADC + HART protocol.

Application
UHC series magnetic column liquid level gauge is widely used in petroleum, chemical industry, oil field, pharmaceuticals industry, food, wine industry etc., suitable for level measurements under the environment of high/low temperature., high pressure, strong corrosion, toxicity. 

 

Contact Us
Sichuan VACORDA Instrument Manufacturing Co., Ltd.
E-mail:    sales@vacorda.com
Tel:            0086-028-87362258
                 7X24 hours online
Address: Guanghua Rd, Qingyang Dist, Chengdu, Sichuan Province, China

* Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible

+86
  • +86 CN
Submit